Table 3.3 - Evidence requirements for Ventilation Openings
| DEAP software tab: “Ventilation" | ||
|---|---|---|
| Ventilation: Infiltration due to openings | ||
|
Guidance on re-use of data for Ventilation - Infiltration due to openings can be found here |
||
| Data Entry Item | Guidance | Documentary Evidence |
| Count of chimneys | Follow DEAP guidance. Note, as per Table 3.1, the specified ventilation rate for chimneys (and open flues) “includes an allowance for the associated permanent vent for air supply, so this vent should not be entered separately”. |
|
| Count of open flues | DEAP guidance must be followed as it distinguishes between open flues, chimneys and room sealed appliances. |
|
| Intermittent fans and background / passive vents | Pay close attention to to the guidance here in relation to trickle vents, controllable vents, and permanently open vents. The minimum open area of 3,500mm2 equates to an (open) circle of 67mm diameter. |
|
| Flueless combustion room heaters | See Ventilation Introduction here. |
|
| Draught lobby |
Sketch/architectural drawings and/or photograph required as supporting evidence for draught lobby set out here. Where a draught lobby is being entered as “Yes” in DEAP ensure sufficient detail is recorded on the sketch/drawings and/or survey form and/or photographs to support all criteria necessary to meet the requirements to be a draught lobby. Note: Apartments with access via an enclosed stairwell or corridor should be classified as having a draught lobby. |
|